uickest way to connect romex to metal box Another guy want's to use a PVC box to house the contactors for an Ansul system. I asked how he was going to handle bonding the conduits and MC cables going into the box. Doesn't seem natural to me either. You see PVC boxes on the shelves of all the big boxes. Never screw cover, hinged cover or rain tight metal boxes. J blocks like I am refering to is an entirely enclosed on all sides box, but there is no electrical box molded into the block. It is a 1 piece outfit, and no building materials are exposed like traditional vinyl boxes.
0 · romex grommet clamp
1 · insert romex into outdoor box
2 · how to secure metal box
3 · how to insert romex box
4 · grommet for romex box
5 · grommet for metal junction box
6 · fixing nm cable to metal box
7 · extending nm cable to box
The best part, imho: New Old Stock Cusheen vinyl countertops to match up with the Youngstown Steel Kitchen cabinet bases. There are a lot of steel kitchen cabinets around (of course, not NOS), and there are a lot of GE ranges around (ditto) .
You either need a NM clamp or some sort of plastic grommet to secure the wire. NM clamps are easier to find in most cases. You need 1/2" clamps, but they may be labeled 3/8". Remember to only remove the . I want to mount this box on the side of the house and come into it through the back hole with romex from inside the house, and then change to stranded THHN to be run in PVC conduit outdoors. I am under the impression . You can transition wiring methods at a junction box. Use the EMT wiring method up to the junction box (whole nine yards with fittings and clamps). Then use the NM wiring method beyond it. The junction box must remain accessible without screws, nails or demolition (other than the ones on the junction box lid, of course).Is it legal to terminate flexible conduit in-wall and continue the romex run to the outlet box? I need to run some wire behind my kitchen base cabinets and then into the wall but it’ll be a lot easier to simply terminate the flexible conduit and continue with the romex to the outlet box rather than running the flexible conduit all the way to the box.
Another guy want's to use a PVC box to house the contactors for an Ansul system. I asked how he was going to handle bonding the conduits and MC cables going into the box. Doesn't seem natural to me either. You see PVC boxes on the shelves of all the big boxes. Never screw cover, hinged cover or rain tight metal boxes.Should I also use a metal box for the lamp I want to add? Also, when I add the handy box, can I splice off the existing wire to add the power supply for the new lamp? If I did this, I think I'd have have 4 ground wires connected to one wire nut. 1 to ground the hand box, 2 to connect the wire I need to cut, and 1 spliced off to the new power . Use a NM clamp. The correct thing to use is not a grommet, but a NM clamp, as the latter grabs the cable's jacket and strain-relieves it to the box.They are available in a few different types (some are metal, others are plastic), and install into a standard 1/2" knockout, either using a locknut (for metal and some plastic types), or simply by snapping into the KO (for some of the .This exposed furring strips on the block walls, with 14/2 Romex running from the joists stapled down the furring strips, feeding into rusted out metal junction boxes. I have already removed the junction boxes and furring strips, and have capped the Romex and stuffed it up into the joists to keep them out of the way.
If the romex is from demolition, just drop it as is at the scrap yard, unless you have a really fast wire stripping rig for scrapping. The scrap yard will pay more for stripped but the work is a lot, they may require you to strip the outer insulation which is easy enough with a good knife, no need to worry about nicking the inner insulation after all. Hi I need to run Romex through a stud wall which is furred out from the exterior cinder block wall. . Might be good with code but when something isn't crystal clear in code it ends up his way or not at all? G. GMc . I'm was getting ready to do something similar by running to the back of a inlet box for a generator but was going to use UF . What is the fastest way to strip romex in switch and receptacle boxes? Save Share Like. Sort by Oldest first . A good razor knife new blade very light touch only way togo. Get in that box like a surgen quick and precise. For 2 wire two light slices at top and bottom and pull. For 3 wire slice a little X at the top of the wire then a 3 .
Am I correct that either way it is not OK to use romex stapled to the trusses to supply power to lights and or a fan? . Also would it be OK to use metal boxes on the trusses? Save Share Reply Quote Like. Sort by Oldest first Oldest first Newest first Most reactions. eastcoastsparky. 189 posts .Specifically, connecting romex to an existing grounded conduit gang box to run to say a ceiling fan or can lights, not running romex cable through conduit pipe itself. Same regard, would plastic gang boxes be acceptable to install in new locations (not replacing the metal gang boxes)? Home is in North Aurora, IL.I'm attempting to install new wall sconces, and the plan is to run 14/2 romex from outlets directly below where the sconces will be up to junction boxes on the wall. It's a finished wall, so I need to use old work boxes that'll just cling to the drywall instead of a stud.
Re: the Romex entering the junction box, the cable will be firmly anchored to a joist within 8" from where it enters the box. Will I still need to install some type of non-abrasive fitting at the point where the Romex enters the junction box, akin to what is required on metal type boxes?I have a detachable platform with electricity (20A 120V) run to it. Because the platform is detachable, the wiring runs through a junction box, and if the platform needs to be detached, I kill the breaker, open the junction box, and disconnect . I reside in CT - Anyone know if I can run my indoor Romex wire through house wall into a metal junction box? From there I'll run Schedule 40 with THHN wire out to endpoints. Core question here is - Can I run Romex through . Thank you! I ended up running the AC cable into a metal box, and then brought romex out and into the plastic box. Worked great. Stuff said: That is AC cable so the sheath is the ground. The short aluminum "wire" is the .
romex grommet clamp
romex and metal box? Thread starter sparks2000; Start date Nov 26, 2009; Status Not open for further replies. 1; 2; 3; Next. 1 of 3 Go to page. Go. Next Last. sparks2000 Senior Member. Location Chicago,IL. Nov 26, 2009 #1 do you have to ground a metal box, if you pull it in romex? e57 Senior Member. Location San Francisco, CA. The boxes are in good shape. I can fish the cables to the boxes relatively easily. It's a one story house with access down into the walls from the attic. That's the way the wires are currently run. My original plan was to pre-attach the connector to the cable, fish it down to the box, and screw on the nut from inside the box. You do not need three wire NM. Two wire (with ground) is all that's needed. You MUST terminate both wires in a metal box. Put the NM ground wire under a ground screw in the threaded hole in the back of the box, every metal box has one. Then just make sure the BX connector is nice and tight in the box. The cable and connector is the ground with BX. In the older versions of the code, you could just tie the ground wires around a screw in the box, such as the 8-32 that is commonly inside boxes to tighten down as a romex clamp. Now you need to use a Green Grounding screw that is .
Mount the boxes with screws and measure. That way you can adjust the boxes if necessary. Morton has ribs on 12” centers which helps a lot. Otherwise surface mount a box on a board as noted above. Drill a hole big enough for a romex connector in the back of the box.
It also prevents the cable from rubbing against the edge of the box and potentially damaging the sheathing. Most plastic boxes have built-in spring tabs that secure the cable as it's pushed into the box. When it comes to metal boxes, there are several different clamping methods you can use, but first, you have to remove a knockout in the box.
You always connect the egc (equipment ground wire) of the romex to the box. If the receptacle or switch is the self grounding type and you use it in a proper metal box you would not be required to connect it, via the green screw on the metal yoke, to the egc of the romex. If this is unfinished walls like in a basement and the switch or receptacle mounts to a metal .If you are using it as a pull box to feed a receptacle in another box, there is a ground fault path in the Romex already, all the way back to the panel. . DirectlyTalkingToYou • He's using a 2 Screw connector on PVC to connect to a metal box, the metal box is part of the electrical system. When pulling that romex through that metallic .
Metal boxes are better when you need the strength and volume to make up a ton of wires. The blank covers fit better than a plastic box. The holes are easily used by adding a romex connector of the right size. I use plastic where ever there is light duty. I use metal for medium to heavy duty. My welder has a metal box What i do: Mount all the boxes. Start roping all my wire, as I land my nm's in boxes I label them with a sharpie (for instance: hot, sl, sl center light, sl perimiter cans etc. All my things are labeled to avoid confusion in case changes happen later. Then, when all my wire (or most of all) is roped stapled and stacked I make the boxes up.